App Available Now
Shop smart. Save big.
Receive the latest updates from Canada Computers and be the first to take advantage of special promotions and events.
Email SubscribeProviding Canada with business solutions for over 25 years. Learn More
Apply for Corporate AccountGive us a call
Toll-Free 1.855.940.2400
Tel: 905.780.2632
Overview
This SmartPro® line-interactive UPS system provides reliable battery backup and AC power protection against blackouts, brownouts, overvoltages, surges and line noise that can damage valuable electronics or destroy data. The SMART1500LCD is ideal protection for small business networks, VoIP systems, point-of-sale applications, desktop workstations, home offices and home theater systems.
Reliable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting.
NEMA 5-15R Outlets Protect Your Connected Components
Eight 5-15R outlets provide connected equipment with PWM sine wave AC output. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART1500LCD can correct brownouts as low as 75V and overvoltages as high as 147V back to nominal 120V power continuously, all while keeping the battery fully charged and ready to take over in case of power failure.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
ENERGY STAR-Certified to Help You Save Money and Protect the Environment
By meeting strict U.S. Department of Energy and U.S. Environmental Protection Agency requirements, this ENERGY STAR UPS system provides high operational efficiency to signal a reduction in BTU emissions, save on utility and cooling costs and help protect the environment.
Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
The large LCD indicates a variety of UPS operational conditions, including voltage, runtime, load, battery and operating mode. The control panel rotates to accommodate both rack-mount and tower configurations. An audible alarm indicates loss of utility power or low battery.
Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and HID-compliant USB ports connect to a computer running free downloadable PowerAlert® software to enable safe unattended system shutdown in case of a prolonged power failure. Cables are included.
Versatile Installation Options
You can mount the SMART1500LCD in just 2U of space in an EIA-standard 19-inch rack using the included hardware. You can also adapt it for tower installation using the included brackets. The six-foot power cord with NEMA 5-15P plug connects to a compatible AC outlet.
Specifications
Output Volt Amp Capacity (VA) | 1500 |
Output kVA capacity (kVA) | 1.5 |
Output Watt Capacity (watts) | 900 |
Nominal Output Voltage(s) Supported | 115v; 120v |
Frequency compatibility | 60 Hz |
Output voltage regulation (line mode) | -18%, +8% |
Output voltage regulation (Battery mode) | 115V (+/- 5%) |
Built-in UPS output receptacles | 8 5-15R outlet(s) |
Basic PDU options | PDU1215 (1U / 13 5-15R outlets); PDUNV (1U / 2 C19, 12 C13 outlets); PDU1415 (0U / 14 5-15R outlets); PDUV15 (0U / 12 5-15R outlets) |
Metered PDU options | PDUMH15 (1U / 13 5-15R outlets); PDUMH15AT (1U / 8 5-15R outlets)*; PDUMV15 (0U / 16 5-15R outlets) |
Switched PDU options | PDUMH15ATNET (1U / 8 5-15R outlets)*; PDUMV15NET (0U / 16 5-15R outlets) |
External PDU redundancy options | *Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS models only |
Output AC waveform (AC mode) | Sine wave |
Output AC waveform (battery mode) | PWM sine wave |
Rated input current (at maximum load) | 8.5A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS input connection type | 5-15P; Space saving right angled input plug |
Input circuit breaker | 10A |
UPS Input cord length (ft.) | 6 |
UPS Input cord length (m) | 1.8 |
Recommended Electrical Service | 15A 120VBATTERY |
Full load runtime (minutes) | 3.5 min. (900w) |
Half load runtime (minutes) | 13 min. (450w) |
DC system voltage | 24V DC |
Battery recharge rate (included batteries) | Less than 4.5 hours from 10% to 90% |
Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
Overvoltage correction | Input voltages between 128 and 147 are reduced by 12% |
Undervoltage correction | Input voltages between 93 and 107 are boosted by 14% |
Severe undervoltage correction | Input voltages between 75 and 92 are boosted by 30% |
LED Indicators | Front panel LCD display |
Front panel LCD display | Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing |
Alarms | Audible alarm indicates power-failure and low-battery conditions |
Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
UPS AC suppression joule rating | 480 |
UPS AC suppression response time | Instantaneous |
UPS Dataline suppression | 1 line TEL / DSL or 10Base T Ethernet protection |
EMI / RFI AC noise suppression | Yes |
Installation form factors supported with included accessories | 4 post 19 inch rackmount (mounting kit included); 2 post 19 inch rackmount (mounting kit included); Tower |
Included mounting accessory description | Pair of mounting ears enable tower and 2-4 post rackmount installation |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 3.5 x 17.2 x 10.5 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 8.9 x 43.8 x 26.7 |
Installed whole system maximum rack depth (inches) | 10.5 |
Installed whole system maximum rack depth (cm) | 26.7 |
Installed whole system total rack space height (rack spaces) | 2U |
Secondary form factor | Tower |
Installed whole system dimensions in secondary form factor (height x width x depth / inches) | 17.2 x 3.5 x 10.5 |
UPS dimensions in secondary form factor (height x width x depth / cm) | 43.8 x 8.9 x 26.7 |
UPS / Power Module weight (lbs) | 29.4 |
UPS / Power Module weight (kg) | 13.3 |
UPS Shipping dimensions (height x width x depth / inches) | 7.5 x 15 x 21.5 |
UPS Shipping dimensions (height x width x depth / cm) | 19 x 38.1 x 54.6 |
Shipping weight (lbs) | 33.4 |
Shipping weight (kg) | 15.2 |
UPS housing material | ABS |
Cooling method | FanENVIRONMENTAL |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 266.1 |
Battery mode BTU / hr. (full load) | 626.7 |
Communications interface | USB (HID enabled); DB9 Serial |
Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
PowerAlert software | Free download from www.tripplite.com |
Communications cable | USB and DB9 Serial cabling included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Transfer time | 2-4 milliseconds |
Low voltage transfer to battery power (setpoint) | 75 |
High voltage transfer to battery power (setpoint) | 147 |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI); Meets FCC Part 68 / Industrie Canada (telecommunications); ROHS (Reduction of Hazardous Substances) |
Standard warranty period | 3 years |
Warranty & Returns
Return Period | 15 Days |
Defective Exchange Period | 30 Days |
Sales Condition | Special-Order Product, Non-Cancellable. Subject to Availability. |
Reviews
Cisco SPA502G 1-Line IP Phone with Display, PoE and PC Port 1 x RJ-7 Headset, 2 x RJ-45 10/100Base-TX , 1 x Sub-mini phone Headphone
MIR = Mail in Rebate, IR = Instant Rebate. Prices are in Canadian dollars. Canada Computers & Electronics is not responsible for typographic or photographic errors. Prices and specifications are subject to change without notice. Promotional pricing is valid while quantities last. Logos and trademarks are copyrighted and the property of their respective owners. Canada Computers & Electronics is independently operated in Quebec. © 2003 - 2024 Canada Computers & Electronics. All rights reserved.